ISSN 2063-5346
For urgent queries please contact : +918130348310

Alprazolam benzoate (APB) determination by the improvement of a micro-high-performance liquid chromatography technology in their dose pharmaceuticals and standard powder

Main Article Content

Khaldoon S. Alhadad1, H. N. K. AL-Salman2*
» doi: 10.48047/ecb/2023.12.5.284

Abstract

Context: This paper aims to explain and develop a high-performance liquid chromatography (HPLC) technique to measure Alprazolam Benzoate (APB) in pharmaceuticals. Method: The form of (APB) was ascertained using the Reversed-Phase HPLC (RP-HPLC) technique, the findings of which were obtained. An Ion Pac column and HPLC-UV system with an Arcus EP-C18 sizing 5 m, 250 mm, and 4.6 mm were used to conduct the chromatographic analysis. Acetonitrile was used as the mobile phase with a 0.5 M potassium dihydrogen orthophosphate + Triethylamine 30:70 (v/v) buffering at pH 4.5 and an average flow rate of 1.0 ml/min. UV detection was performed by the HPLC equipment at 310 nm.

Article Details